Product Details:
|
| Highlight: | Laboratory Wet Laser Particle Size Analyzer,Accurate Wet Laser Particle Size Analyzer |
||
|---|---|---|---|
The NKT5600-H intelligent fully automatic laser particle size analyzer integrates multiple innovations and patented technologies to achieve a breakthrough upgrade in particle size detection performance. The instrument features an advanced dual-lens optical system combined with a new-generation forward, side, and backward detector array, significantly expanding the measurement range and comprehensively enhancing overall performance.
The hardware system has been fully upgraded with a fifth-generation ultra-high-speed signal acquisition motherboard, greatly improving the comprehensiveness and accuracy of scattered light signal collection. The exterior uses an internationally advanced argon-gas-protected injection molding process for one-shot forming, resulting in a lightweight body with elegant texture and excellent corrosion resistance.
| Parameter | Specification |
|---|---|
| Measurement Principle | Full-range Mie scattering theory |
| Particle Size Range | 0.01 μm – 1500 μm (full-range measurement) |
| Detector System | 96 channels, uniform cross and area-compensated multi-direction laser array |
| Laser | Imported high-power fiber-coupled semiconductor laser, wavelength 635 nm, max power 20 mW |
| Laser Management | LIMS Laser Intelligent Management System |
| Optical Model | Full-range Mie scattering theory, including high-concentration multiple scattering dynamic compensation |
| Filtering Method | Dual-lens filtering technology: Fourier transform lens + filtering lens |
| Acquisition Motherboard | 16-bit, 200 kbps ultra-high-speed acquisition motherboard |
| Concentration Range | Minimum obscuration 3%, maximum obscuration 90% (optical concentration) |
| Sample Cell | Special coating treatment, optical signal transmittance >99.7% |
| Protection Functions | Ultrasonic dry-burn protection, liquid level sensor, overflow pipe, no response to incorrect operations |
| Ultrasonic Power | 50 W/60 W optional, adjustable power ultrasonic optional |
| Alignment System | Fully automatic alignment with mechanical center + optical center dual positioning |
| Measurement Time | Typical <10 seconds |
| Measurement Accuracy | Accuracy and repeatability Dv50 both better than ±0.5% (NIST traceable reference material) |
| Measurement Mode | SOP editable fully automatic measurement |
| Ambient Temperature | 0 °C – 45 °C |
| Ambient Humidity | 10% – 85% relative humidity (non-condensing) |
| Power Requirements | 220 V (±20 V), 50 Hz – 60 Hz |
| Applicable Standards | ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 |
| Dimensions | 820 mm * 310 mm * 330 mm |
| Instrument Weight | 32 kg |
Built-in editable SOP (Standard Operating Procedure). With a single key press, the instrument automatically executes the entire test process including water filling, bubble removal, background measurement, sample dispersion, data acquisition, saving, and cleaning.
Integrates an advanced LIMS Laser Intelligent Management System, enabling precise intelligent control of the laser source. The system monitors the optical path status in real time, instantly activates the laser upon receiving a test command, and reaches a stable working state within 3 seconds.
Equipped with a revolutionary sample window quick-change device, featuring a user-friendly buckle and guide structure design. Without any tools, users can complete the entire disassembly and assembly of the sample window within 10 seconds.
Comes with professional particle size analysis software, integrating a powerful database and multi-dimensional reporting system. Supports multi-format report export and custom editing, as well as side-by-side comparison of multiple data sets.
Adopts an innovative dual-lens design in which a Fourier transform lens and a filtering lens work together. This technology creates a pure single-optical-path detection environment, effectively filtering out unnecessary stray light interference.
Equipped with a fifth-generation ultra-high-speed signal acquisition motherboard, achieving an ultra-high sampling frequency of 10,000 times per second. Completes comprehensive, omission-free synchronous capture of all particle scattering signals.
The core photodetector array features the 6th generation high-stability photodetector independently developed by NKT. Using specially selected high-performance German-imported raw materials, it possesses excellent oxidation and aging resistance.
Equipped with an intelligent active anti-fog system that monitors real-time environmental temperature and humidity changes, providing millisecond-level early warning and rapid response to the risk of sample window fogging.
Pioneering an optical path dual alignment system that integrates both mechanical alignment and optical alignment technologies. Achieves one-key start, instantaneous precise alignment, completely eliminating tedious manual adjustments.
Adopts an innovative flow path system design, fully optimizing pipeline layout and drainage structure. The core incorporates a patented self-cleaning circulation pump whose special structure ensures no liquid residue remains after testing.
Adopts a professional integrated airtight dustproof system and vibration-proof design, effectively isolating external dust ingress and vibration transmission. Ensures long-term stability and precise focusing of the core optical system.
Optional high-precision automatic dispersant dosing system. This system is seamlessly integrated with the instrument's intelligent SOP and can automatically add a precise amount of dispersant during the test according to preset methods.
Built-in comprehensive intelligent anti-error protection system, combining hardware interlocking and software intelligent judgment. The system detects non-compliant operations in real time, immediately triggers active alerts and execution interruption.
Specifically designed to ensure measurement accuracy in harsh environments. The system integrates high-precision sensors and intelligent algorithms to monitor the microenvironment inside the instrument's core optical system in real time.
The NKT5600-H exhibits excellent repeatability, with measurement results remaining highly consistent across multiple experiments. This outstanding repeatability stems from the instrument's precision optical system design and stable laser source.
Possesses excellent accuracy and resolution. Through its precise optical system and advanced data processing algorithms, it performs high-precision particle size distribution measurements. Resolution reaches the 0.01-micron level.
For further information or to discuss your specific requirements, please contact us directly.
Contact Person: Miss. Scarlett.S
Tel: 8616602956098